{"id":638,"date":"2021-10-12T13:27:10","date_gmt":"2021-10-12T13:27:10","guid":{"rendered":"https:\/\/oshablue.com\/doc\/?p=638"},"modified":"2021-10-12T13:31:35","modified_gmt":"2021-10-12T13:31:35","slug":"firmware-flash-cables","status":"publish","type":"post","link":"https:\/\/oshablue.com\/doc\/firmware-flash-cables\/","title":{"rendered":"Firmware Flash Cables"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_68 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<label for=\"ez-toc-cssicon-toggle-item-69ea4678058c4\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-69ea4678058c4\"  aria-label=\"Toggle\" \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/oshablue.com\/doc\/firmware-flash-cables\/#SPI_CCC_or_FPGA_Flash_7-pin\" title=\"SPI (CCC or FPGA) Flash (7-pin)\">SPI (CCC or FPGA) Flash (7-pin)<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/oshablue.com\/doc\/firmware-flash-cables\/#Cable-to-Board_Adapter\" title=\"Cable-to-Board Adapter\">Cable-to-Board Adapter<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/oshablue.com\/doc\/firmware-flash-cables\/#MCU_Flash_6-Pin\" title=\"MCU Flash (6-Pin)\">MCU Flash (6-Pin)<\/a><\/li><\/ul><\/nav><\/div>\n\n<p>Software programming tools and the programming cable with an adapter, if needed, are used to update the firmware on the DL and HDL family hardware.<\/p>\n\n\n\n<!--more-->\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"SPI_CCC_or_FPGA_Flash_7-pin\"><\/span>SPI (CCC or FPGA) Flash (7-pin)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The <a href=\"https:\/\/oshablue.com\/doc\/category\/hdl-0104-rs104\/\">RS104 (HDL-0104-RS104)<\/a> and <a href=\"https:\/\/oshablue.com\/doc\/category\/hdl-0108-rscpt-8-chan-mod-rapid-scan\/\">RSCPT 8-Channel (HDL-0108-RSCPT)<\/a> can have their &#8220;CCC (FPGA)&#8221; flash memories updated using 7-wires of the USB-SPI cable, and the software toolchain described in these posts: <\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/oshablue.com\/doc\/windows-10-fresh-atom-ide-apio\/\n\">https:\/\/oshablue.com\/doc\/windows-10-fresh-atom-ide-apio\/<\/a><\/li><li><a href=\"https:\/\/oshablue.com\/doc\/mac-os-x-10-15-catalina-fresh-atom-ide-apio\/\">https:\/\/oshablue.com\/doc\/mac-os-x-10-15-catalina-fresh-atom-ide-apio\/<\/a><\/li><\/ul>\n\n\n\n<p>There are additional methods for updating these firmware images as well.  Please ask.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Cable-to-Board_Adapter\"><\/span>Cable-to-Board Adapter<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>While the 8-Channel <a href=\"https:\/\/oshablue.com\/doc\/category\/hdl-0108-rscpt-8-chan-mod-rapid-scan\/\">RSCPT (H<\/a>DL-0108-RSCPT) uses a standard 100-mil header for updating this firmware, the <a href=\"https:\/\/oshablue.com\/doc\/category\/hdl-0104-rs104\/\">RS104 (HDL-0104-RS104)<\/a> requires an adapter to bridge the physical connection from the USB-SPI cable to the smaller socket on the hardware itself.  The image here shows the correct connection of the USB-SPI cable&#8217;s wires to the adapter.  From Pin 1, the correct order of wires from the USB-SPI cable, by color is:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Black<\/li><li>Gray<\/li><li>Green<\/li><li>Orange<\/li><li>Yellow<\/li><li>Blue<\/li><li>White<\/li><li>(Unused: Purple, Brown, Red)<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"561\" height=\"191\" src=\"https:\/\/oshablue.com\/doc\/wp-content\/uploads\/2021\/10\/image-1.png\" alt=\"\" class=\"wp-image-640\" srcset=\"https:\/\/oshablue.com\/doc\/wp-content\/uploads\/2021\/10\/image-1.png 561w, https:\/\/oshablue.com\/doc\/wp-content\/uploads\/2021\/10\/image-1-300x102.png 300w\" sizes=\"auto, (max-width: 561px) 100vw, 561px\" \/><figcaption>Connection order of USB-SPI wires (right hand side of image) to RS104 adapter (left hand side of image).  Note the position of the Pin 1 &#8220;Arrow&#8221; on the 100-mil housing on the left.  Order of wires starting from Pin 1 is: Black, Gray, Green, Orange, Yellow, Blue, White.  Purple, Brown and Red are unused in this application.  Here as shown, electrical tape or similar is used to temporarily organize the single-pin wire housings on the USB-SPI cable&#8217;s pigtail.<\/figcaption><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"MCU_Flash_6-Pin\"><\/span>MCU Flash (6-Pin)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Use MPLABX and the standard 100-mil header or, for the <a href=\"https:\/\/oshablue.com\/doc\/admplex-integration\/\">ADMPlex<\/a> and <a href=\"https:\/\/oshablue.com\/doc\/category\/hdl-0104-rs104\/\">RS104<\/a>, the custom 100-mil-to-compact-form adapter cable.  The pin order matches the standard Microchip programming adapter pin order (see the PICKit 3 or 4, or the 100-mil-to-RJ45 adapter for the ICD3, etc.).  Make sure Pin 1 is oriented correctly!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Software programming tools and the programming cable with an adapter, if needed, are used to update the firmware on the DL and HDL family hardware.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[18,15,53,40,50,32,25,13,14,52,12],"tags":[],"class_list":["post-638","post","type-post","status-publish","format-standard","hentry","category-hdlite-accessories","category-hdlite-family","category-admplex","category-firmware","category-hdl-0104-rs104","category-hdl-0108-rscpt-8-chan-mod-rapid-scan","category-lattice-semi","category-ndt","category-new-prototypes","category-rs104","category-ultrasonics","entry"],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/posts\/638","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/comments?post=638"}],"version-history":[{"count":3,"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/posts\/638\/revisions"}],"predecessor-version":[{"id":643,"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/posts\/638\/revisions\/643"}],"wp:attachment":[{"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/media?parent=638"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/categories?post=638"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oshablue.com\/doc\/wp-json\/wp\/v2\/tags?post=638"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}